Sona
Nzyme Sona sensors are the recommended choice for all production environments. Fully supported by Nzyme, they offer plug-and-play setup with no drivers required, and are available in a range of enclosure options. Hardware support and warranty are provided directly by Nzyme Precision Industries, the company behind Nzyme.
Using Sona in nzyme-tap
Connect your Sona board(s) to the host running nzyme-tap and run nzyme-util to
generate a configuration snippet your can copy and paste into your nzyme-tap.conf file:
This will generate a configuration snippet that makes use of all connected Sona boards, splitting channels evenly.
==> Sona Configuration Generator
Generating configuration for all connected Sona devices.
[>] Detecting connected Sona devices...
[*] Found 1 Sona (4 interfaces).
Detected Interfaces:
[1] sona-7C9085C8E6BDAAD1
[2] sona-8B7B63E05F374C94
[3] sona-B47277283036FD2F
[4] sona-1ABAE79791F91419
==> Generated Configuration
Copy the block between the markers below into your nzyme tap
configuration file. Channels are split evenly across all interfaces.
---------- BEGIN CONFIGURATION ----------
[wifi_interfaces.sona-7C9085C8E6BDAAD1]
active = true
channels_2g = [1, 2, 3, 4, 5, 6, 7]
channels_5g = []
[wifi_interfaces.sona-8B7B63E05F374C94]
active = true
channels_2g = [8, 9, 10, 11, 12, 13, 14]
channels_5g = []
[wifi_interfaces.sona-B47277283036FD2F]
active = true
channels_2g = []
channels_5g = [36, 40, 44, 48, 52, 56, 60, 64, 100, 104, 108, 112, 116, 120]
[wifi_interfaces.sona-1ABAE79791F91419]
active = true
channels_2g = []
channels_5g = [124, 128, 132, 136, 140, 144, 149, 153, 157, 161, 165, 169, 173, 177]
----------- END CONFIGURATION -----------
[*] Configuration generated for 4 interfaces.
Engagement interfaces configuration works the same way with all WiFi adapter types, including Sona.
Upgrading Sona Firmware
Upgrading Sona firmware is described in the corresponding nzyme-util section.